Nouh, S.A. and Mohamed, A. and Bahareth, R.A. and Abutalib, M.M. and Benthami, K. (2014) Color changes in X-ray irradiated PM-355 and Makrofol de 7-2 nuclear track detectors. EPJ Applied Physics, 65 (3).

Full text not available from this repository.
Official URL: https://www.scopus.com/inward/record.uri?eid=2-s2....

Abstract

Effects of X-ray irradiation on the color changes of PM-355 and Makrofol DE 7-2 nuclear track detectors have been investigated. Samples from PM-355 and Makrofol DE 7-2 polycarbonates were irradiated with X-ray doses at levels between 10 and 250 kGy. The transmission of these samples in the wavelength range 370-780 nm, as well as any color changes, was studied. The Commission International de E'Claire (CIE units x, y and z) methodology was used in this work for the description of colored samples. The color differences between the non-irradiated sample and those irradiated with different X-ray doses were calculated. The results indicate that both PM-355 and Makrofol DE 7-2 detectors acquire color changes under X-ray irradiation, but the PM-355 detector has more response to color change than that of Makrofol DE 7-2. © 2014 EDP Sciences.

Item Type: Article
Uncontrolled Keywords: Color changes; Color difference; Nuclear track detector; PM-355 detector; Wavelength ranges; X ray irradiation; X-ray dose, Detectors; Irradiation; X rays, Colorimetry